email  l  1-905-752-2202

 
 
   
 
 
Applications
     • Airborne
     • Archaeology
     • Earthquake Research
     • Education & Research
     • Enviro -Engineering
     • Mineral Exploration
     • Observatory Apps
     • Unexploded Ordnance
     • Volcanology

  Products
     • Overhauser
     • Potassium
     • Proton 
     •
Airborne
     • Scalar   
     • SuperGrad
     • Vector  
     • Calibration
     • Accessories  
     •
VLF

  Quotations
     • Overhauser
     • Potassium
     • Proton
     • Airborne
     • Vector Observatory
     • Scalar Observatory
     • SuperGrad
     • Base_Station
     • Gamma Proton

  Technology
     • About Mags
     • Technologies
     • GPS
     • Software
     • 3rd Party Software
     • Tech Notes & Papers
     • Quantum E-News
     • Support

 


 
Contact

     • Contact GEM
     • By Country
     • Feedback Form 

     • Support

About GEM
     • Corporate Profile
     • Job Opportunities
     • Privacy Policy
     • News Archives
     • Site Map
 

 

Gem Systems

 

  
Scalar Magnetometers

Many magnetic observatories today rely on a combination of scalar, fluxgate and theodolite instruments for obtaining measurements. Research installations engaged in volcanology applications are also using scalar magnetometers for stationary work.

GEM’s Overhauser GSM-90 EUROMAG is particularly suited to these applications (and volcanology). This is a standard magnetometer without a display screen that can be operated via computer.


Observatory and Volcanology Applications

Up until about 10 years ago, magnetic observatories around the globe used fluxgate magnetometers as their primary tools to monitor the earth's magnetic field. But fluxgates have the disadvantage that they must be periodically calibrated to maintain the level of absolute accuracy that is so important in observatory research.

By using an Overhauser magnetometer (EUROMAG) together with a fluxgate magnetometer, both total field and field direction information can be collected with a very high degree of absolute accuracy. (Users may also be interested in the GEM's new Suspended dIdD magnetometer which can be accessed via the Vector Magnetometers product page.)

The EUROMAG instrument is the total field magnetometer / gradiometer of choice for customers who require:

• Minimal drift (0.05 nT / year)
• Continuous, stable measurement
• High absole accuracy (0.2 nT)
• High sensitivity
• Reliability (packaged in a tick, waterproof aluminum casing)
• Convenient operation (RS-232C used for control and acquisition)
• Low power operation (2Ws per reading - 0.5W average for 1 reading every 5 seconds)

The GSM-90 can be thought of as an Overhauser magnetometer (GSM-19) that has been simplified for long term monitoring applications. It has no keyboardd, no battery and no memory for data storage. It is controlled by a terminal such as a Personal Computer which allows for its operation to be completely automated.

EUROMAG Benefits

The GSM-90 is a high sensitivity Overhauser effect magnetometer. Main benefits include:

The instrument is a secondary standard for measurement of the Earth’s magnetic field. The system has 0.01nT resolution, and 0.2nT absolute accuracy over its full temperature range.

The GSM-90 is available in two versions – a slow reading version and a fast reading version for flexibility. Each consists of one (170x70mm) cylindrical sensor, and a sturdy aluminum package (220x245x70mm) which contains all the unit’s electronics.

The instrument is microprocessor based for full remote control capability and time-savings. The results of measurement are available in serial form (RS-232-C interface) for collection by data acquisition systems, terminals or computers. The same RS-232 link provides the means of control to the instrument.

Understanding the GSM-90 Measuring Sequence

The GSM-90 is a compact version of the GSM-19 Overhauser magnetometer that:

• Cycles from 0.2 seconds to 1 hour (depending on the version - Fast or Slow)

• Includes a standard “Observatory” mode. Observatory mode measures over 5 second intervals and outputs an average value every minute. The time of the averaged reading is considered to be the time of the middle reading.

• Can optionally be equipped with an AC deflect pulse (long or short) in order to minimize interference with other observatory instruments.

The instrument does not have a keyboard and display; therefore, all control of the instrument is through a computer or terminal.

GEMLinkW (PC Software) supplied with GSM-90 can be used for this purpose. Any other communication software commercially available (like Xtalk, Flashlink Mirror, Hyperlink etc.) capable of sending and receiving RS232 can also be used. Communication is very simple and requires sending only few bytes to the magnetometer.

For more information

The EUROMAG takes advantage of many of the benefits of the Overhauser system as described in the Overhauser product pages. You can also refer to the technical papers on this site and the GSM-90 brochure.

If you would like information specific to your work, please visit our Quotations area and submit a Request for Quotation. We would be delighted to provide you with a no-obligation quote suited to your exact needs.




GEM Advanced Magnetometers.
Our World is Magnetic.



 

Delta Mining Press Release Gradient surveying with Gem Overhause Magnetometer

CNN Money (2/3/2010)

 

Updated Requirements for Obtaining High Accuracy with Proton Magnetometers (11/01/2010)

GEM Systems VLF Option for Ground and Airborne Applications (24/05/2009)

Quantum v11 E-News (17/02/2009)

NEW GEMLink 4.0 Software for PC  (2/2/2009)

Site Characterization Using Overhauser Magnetometer  (10/2/2008)

Advantages of  Selecting an Overhauser (8/14/2008)

High Sensitivity Magnetic Observatory IUGG 2007 Perugia, Italy (7/3/2007)

Quantum v10

E-News (4/29/2007)